Sidebar
Schneider Electric U/UTP, CAT6 Cable - (VDICD116218)
₼0.00
Viewed 1667 times
Categories
Cart
Account
Search
Recent View
Shopping Cart
×
Your shopping cart is empty!
Search
×
Recent View Products
×
Product Description
Schneider Electric U/UTP, CAT6 Cable - (VDICD116218)
Copper LAN cable, Actassi, U/UTP, 4P, Cat6, Euroclass D, 250MHz, LSZH, 500m
Specifications
- range: Actassi
- product or component type: Copper cable
- cable packaging: Drum of 500 m
- color tint: Green
- cable shielding type: U/UTP
- type of cable: 4 pair cables
- communication network category: 6
- remote powering:
- PoE 15W (Power over Ethernet)
- PoE+ 30W (Power over Ethernet Plus)
- 4PPoE 100W (Power over Ethernet)
- communication network type: 1000BASE-T
- minimum return loss:
- Guaranteed: 20.1 dB at 100 MHz typical: 23 dB
- Guaranteed: 17.3 dB at 250 MHz typical: 19 dB
- attenuation:
- Guaranteed: 19.9 dB Typical: 19.1 dB @ 100 MHz
- Guaranteed: 33 dB Typical: 32 dB @ 250 MHz
- power sum near-end crosstalk [PSNEXT]:
- Guaranteed: 42.3 dB at 100 MHz
- Guaranteed: 36.3 dB at 250 MHz
- attenuation to Crosstalk Ratio Far-end [ACRF]
- Guaranteed: 28 dB at 100 MHz
- Guaranteed: 20 dB at 250 MHz
- power sum attenuation crosstalk ratio far-end [PSACRF]
- 25 dB at 100 MHz
- 17 dB at 250 MHz
- near end crosstalk [NEXT]
- Guaranteed: 45.3 dB at 100 MHz
- Guaranteed: 39.3 dB at 250 MHz
- input impedance: 100 Ohm
- transverse conversion loss: >= 40 - 10 x log(f) dB from 1…250 MHz conforming to IEC 61156-5, ed. 2.1
- segregation class: Class b conforming to EN 50174-2
- pulling force: 140 N
- bending radius
- Minimum bending radius during installation: 8 x overall diameter
- Minimum bending radius after installation: 4 x overall diameter
- material
- Solid bare copper: conductor
- PE (polyethylene): wire insulation
- PE (polyethylene): sheath
- euroclass level: Dca s2 d2 a2
- nominal velocity propagation: 68 %
- AWG gauge: AWG 23
- calorific value: 599 MJ/km
- cable outer diameter: 5.9 mm
- cable weight: 40.9 kg / 1 km
- ambient air temperature for installation: 0…50 °C
- ambient air temperature for storage: -20…60 °C
- ambient air temperature for operation: -20…60 °C
- directives
- 2006/95/EC - low voltage directive
- 305/2011/EU - construction product regulation
- flame retardance: LSZH
- standards
- ISO/IEC 11801-ed. 3 performance
- EN 50173-1 performance
- EN 50174-1 performance
- ANSI/TIA/EIA-568-C.2 performance
- IEC 61156-5-ed. 2.1 performance
- EN 50288-6-1 performance
- ISO/IEC 14763-2 installation standards
- EN 50174-2 installation standards
- IEC 60332-1 flame propagation characteristics
- IEC 60754-1
- IEC 60754-2 acidity of combustion gases
- IEC 61034 smoke generation
- local pickup (immediately)
- 1 to 3 business days (free delivery over 50 AZN)
- express shipping & special shipping options (contact with the seller)